OptametraCompanyProductsApplicationsNews & PressContact & Support
OM4106 Coherent Lightwave Signal Analyzer
PRODUCTS
OM2014nLaser™ offers 2 or 4 tunable C- and L-band sources
read more >

OM4005Coherent Lightwave Signal Analyzer™
read more >


NEWS & EVENTSproduct OM4106 enables visualization and measurement of complex-modulated signals in fiber
read more >


VIDEO
OM3005 VideoOM4106 Coherent Lightwave Signal Analyzer view video>


LeCroy ScopeOM4106B Coherent Lightwave Signal Analyzer Pro™

Download Optametra OM4106 Tektronix Literature[PDF]
Download Optametra OM4106 LeCroy Literature[PDF]

Key Features

  • Optametra's superior user interface offers comprehensive visualization for ease-of‐use combined with the power of MATLAB1
  • Signal Analysis Software Pro™ included with OM4106B
  • Complete coherent signal analysis system for polarization-multiplexed QPSK, offset QPSK, QAM, differential BPSK/QPSK, and other advanced modulation formats
  • Displays constellation diagrams, phase eye diagrams, Q-factor, Q‐plot, Spectral‐plots, Poincaré sphere, extracted laser phase characteristics, BER, with additional plots and analyses available in the ProTM MATLAB interface
  • Pro™ enables access to internal functions with a direct MATLAB interface
  • Optametra Signal Analysis Suite tolerates > 1 MHz instantaneous signal laser linewidth - compatible with standard network tunable sources
  • No laser phase or frequency locking required
  • Smart polarization separation follows signal
  • Incorporates Optametra OM3105 Coherent Modulation Receiver (CMR™) for high stability, linear, polarization-diverse, optical field detection
  • Includes Signal and Reference tunable laser sources in OM4106B
  • Runs with LeCroy, Tektronix, and Agilent real‐time oscilloscopesTek Scope

Introduction
Optametra's OM4106B Coherent Lightwave Signal Analyzer Pro™ is a new 1550 nm (C‐ and L‐band) fiber optic test system for visualization and measurement of complex-modulated signals, offering a complete solution to testing both coherent and direct-detected transmission systems. Optametra's hardware includes the OM3105 polarization‐diverse Coherent Modulation Receiver™ (CMR™) enabling simultaneous measurement of modulation formats important to advanced fiber communications, including dual‐polarization (DP) QPSK. Optametra's software performs all calibration and processing functions to enable real‐time burst‐mode constellation diagram display, eye‐diagram display, Poincaré sphere, and bit‐error detection. Working with a real‐time oscilloscope of sufficient bandwidth, bit rates exceeding 160 Gb/s (DP‐QPSK) can be analyzed.

Optametra User Interface (OUI)
The common thread through the Coherent Lightwave Signal Analyzer product line is the OUI which governs the operation and display of data. Color‐grade, persistence, and color‐key options are available to help you visualize the data. In the example below, the horizontal transitions are more rare than the vertical transitions due to the relative timing of the I and Q data sequence (upper middle). The other polarization constellation is shown in color grade with only the symbol points (lower middle). Color grade is also available for the eye‐diagram (bottom right).

Optametra User Interface

Figure 1. Optametra OM4106 User Interface showing some color‐grade graphics options. Symbols can also be colored to a key indicating prior state. Data shown is 112 Gb/s PM‐QPSK.

 

Specification Highlights and Overview
Values stated in the following tables are typical unless stated otherwise (some values oscilloscope limited)

Coherent Lightwave Signal Analyzer Pro
Maximum detectable baud rate Greater than 40 Gbaud
Maximum detectable bit rate for DP‐QPSK Greater than 160 Gb/s
Sample Rate 80 Gs/s
O/E Gain imbalance between I & Q 0.1 dB
Available modulation formats OOK, BPSK, DBPSK, DP‐BPSK
DQPSK, DP‐QPSK, QAM, Offset QPSK
Any PRBS or user supplied pattern
Contact factory for new modulation formats

 

OM3105B Coherent Receiver – (included with OM4106B)
Optical input C‐Band 1530 to 1570 nm
  L‐Band 1570 to 1610 nm ‐ optional
Maximum input power +15 dBm
Maximum input power damage level +20 dBm
Additional Items
Electrical bandwidth 30 GHz minimum, 32 GHz with equalization for OM4106B, future­proof upgradable platform, as new scope bandwidths become available higher receiver bandwidths will become available
Optical phase angle of
I-Q mixer after correction
90° ±1°

 

Measurement Display and Analysis Tools (OM4106B)
Constellation diagram
Constellation Elongation
Constellation phase angle
Constellation alignment (bias, phase angle)
Constellation mask
Eye diagram for I and Q
Eye decision threshold Q‐factor
Decision threshold Q plot
Phase diagram
Signal spectrum and laser spectrum
Raw data available in MATLAB
Phase vs. Time available in MATLAB
Frequency offset available in MATLAB
I-bias; Q‐bias
Poincaré sphere
Signal Quality
Tributary skew
CD Compensation
Oscilloscope Delay Compensation
Cable Delay Compensation
Calibration Routines
Full access to internal functions via MATLAB interface
Raw data replay with different parameter setting
Bit error ratio measurements
Off‐line processing

 

General Characteristics – Scope not Included (OM4106B)
Size assembled (H x W x D) 8.9 cm x 43.2 cm x 29.85 cm / 3.5 in x 17.0 in x 11.75 in
Weight net 11.8 kg / 26 lbs
Weight shipping 15.9 kg / 35 lbs
Operating temperature range +10° C to +35° C
Storage temperature range ‐20° C to +70° C, non-­‐condensing humidity
Humidity 15% to 80% relative humidity, non-­‐condensing
Power requirements 115 – 230 V~ 50–60 Hz, 1 power cable, Max. 100 VA

 

Calibration and Warranty
Calibration interval 1 year
Limited warranty (OM4106B) 1 year, On Support -­ extended calibration and service plan available OM4106B.

 

Ordering Information and Options

Model Numbers 4106B
OM4106B -100 Coherent Lightwave Signal Analyzer Pro ‐ with 4 channel 30 GHz receiver, 32 GHz w/Equalization
OM4106B -150 Local Oscillator Externally Connected ‐ Optional
OM4106B -400 QAM and Offset QPSK – Optional
OM4106B -600 Customer's Hybrid Calibration Kit
(Hardware + Software) ‐ Optional
OM4106B -650 On-­‐site Calibration Training
(requires Calibration Kit) - Optional
OM4106B ‐800 On Support ‐ Extended Calibration and Service Plan ‐ Optional
OM4106B ‐801 On Support ‐ Extended Service Plan ‐ Optional
OM4106B ‐802 On Support ‐ Extended Calibration Plan ‐ Optional

Please contact Optametra Sales (sales@optametra.com) for a price quote or to arrange a demonstration. All product descriptions and specifications are subject to change without notice.

 